โญ 10/10 Life Sciences Learning • B10logy = 10 out of 10 in Biology • High-Yield Visual Notes Across 23 Disciplines Explore Subjects →

Exp 5: Single-Particle Cryo-EM Vitrification, CTF Fitting & Fourier Shell Correlation (FSC = 0.143)

Experiment 05Cryo-EM BiophysicsResolution Assessment

Single-Particle Cryo-EM Vitrification, Contrast Transfer Function (CTF) Fitting & Fourier Shell Correlation (FSC)

Lab Duration: 4 Hours • Plunge Freezing • Relion/CryoSPARC Workflow
๐ŸŽฏ Aim: To prepare amorphous vitreous ice cryo-grids of macromolecular complexes via rapid plunge freezing into liquid ethane, screen ice quality under transmission electron microscopy, fit CTF Thon rings, and determine the 3D reconstruction resolution limit using the gold-standard Fourier Shell Correlation ($text{FSC} = 0.143$) criterion.

๐Ÿ”ฌ Principle & Cryo-Microscopy Physics

Biological macromolecules cannot survive the high vacuum and electron radiation of electron microscopy in liquid water. Normal freezing causes water to form hexagonal or cubic ice crystal lattices, which expand by $sim 9%$ and destroy protein quaternary architecture while producing strong Bragg diffraction artifacts. To preserve native hydrated structure, the specimen is vitrified by cooling at $> 10^5,^circtext{C/s}$ into liquid ethane ($text{melting point } -183^circtext{C}$, high thermal capacity), freezing water into an amorphous glass-like solid without periodic crystalline lattices.

In transmission electron microscopy, phase contrast dominates over amplitude contrast. The image is modulated by the Contrast Transfer Function (CTF) of the objective lens:
$$text{CTF}(s) = -sinleft(pi lambda Delta z s^2 + frac{1}{2} pi C_s lambda^3 s^4 – alpharight)$$
where $s$ is spatial frequency ($1/d$), $lambda$ is electron de Broglie wavelength ($0.0197,text{ร…}$ at $300,text{keV}$), $Delta z$ is objective lens defocus (typically $1.0 – 2.5,mutext{m}$ underfocus), and $C_s$ is spherical aberration. Oscillations of the CTF produce concentric dark and bright rings (Thon rings) in the power spectrum of the micrographs. Correcting for CTF phase reversals is mandatory for sub-nanometer reconstruction.

The global resolution of the final 3D reconstruction is established using Fourier Shell Correlation (FSC) between two completely independent halves of the particle dataset (the “gold standard” protocol to avoid noise overfitting):
$$text{FSC}(s) = frac{sum_{s_i in s} F_1(s_i) cdot F_2^*(s_i)}{sqrt{sum_{s_i in s} |F_1(s_i)|^2 sum_{s_i in s} |F_2(s_i)|^2}}$$
The nominal spatial resolution is defined where the FSC correlation curve drops below the theoretical $0.143$ cutoff, corresponding to a signal-to-noise ratio where the phases of the reconstruction have an expected error of $< 60^circ$ (equivalent to an $R_{text{free}}$ crystallographic benchmark).

FIG 5.1: CRYO-EM VITRIFICATION & GOLD-STANDARD FOURIER SHELL CORRELATION (FSC)PLUNGE-FREEZING APPARATUSLiquid N2 Jacket (−196°C)Liquid Ethane (−183°C)High Heat Capacity LiquidHoley Carbon GridRapid Plunge >105 °C/sVITREOUS ICE• Prevents cubic ice crystal lattices• Preserves native hydrated stateGOLD-STANDARD FSC CURVE1.00.70.50.1430.0FSC Correlation00.1 (10Å)0.2 (5Å)0.35 (2.8Å)Spatial Frequency (1 / Resolution Å-1)FSC = 0.143 (Gold Standard)RESOLUTIONd = 2.8 Å NominalTwo independently refined half-map Fourier shell cross-correlation

Figure 5.1: Plunge freezing vitrification scheme and resolution determination by the gold-standard FSC = 0.143 criterion.

๐Ÿ“‹ Step-by-Step Vitrification & Processing Protocol

  1. Grid Glow-Discharge: Glow-discharge Quantifoil holey carbon copper/gold grids (e.g., R 1.2/1.3, 300 mesh) in a plasma cleaner for 45 seconds at $15,text{mA}$ under an air/argon atmosphere to render the hydrophobic carbon film hydrophilic.
  2. Plunge-Freezing (Vitrobot): Condense ethane gas into the central brass cryostat cooled by surrounding liquid nitrogen ($-196^circtext{C}$). Mount the glow-discharged grid in Vitrobot tweezers at $100%$ relative humidity and $4^circtext{C}$. Apply $3.0,mutext{L}$ of protein sample ($1.0 – 2.0,text{mg/mL}$), blot with filter paper for $3.0,text{seconds}$ (blot force 0), and instantly plunge into liquid ethane. Transfer frozen grids into liquid nitrogen storage boxes.
  3. Cryo-Screening & Data Collection: Load grids into a $200 – 300,text{keV}$ cryo-TEM (e.g., Titan Krios) equipped with an energy filter and direct electron detector (Gatan K3). Inspect grid squares: ideal ice appears light grey without crystalline diffraction spots; particles are clearly visible within the holes without aggregating at the air-water interface.
  4. CTF Estimation: Run CTFFIND4 or Patch CTF in Relion/CryoSPARC to fit Thon rings in the power spectrum up to $3.0,text{ร…}$ resolution. Micrographs exhibiting severe drift, astigmatism, or ice contamination are discarded.
  5. 2D/3D Classification & Gold-Standard FSC: Pick $sim 200,000$ single particles. Perform reference-free 2D classification to eliminate false picks and broken particles. Divide remaining particles randomly into two independent half-datasets. Refine each half independently against low-pass filtered initial models ($60,text{ร…}$) and calculate the FSC curve. Read out the spatial frequency at $text{FSC} = 0.143$ to report global resolution in ร…ngstroms.
Advertisement
๐Ÿ“– Key Terms & Comprehensive Glossary

Key Terms in this Lecture • Structural Biology

Master the essential vocabulary, core concepts, and biochemical keywords covered in this chapter. Click any key term to inspect its rigorous definition in the Structural Biology Comprehensive Glossary.

โญ 10/10 Concept Clarity
Back to Structural Biology Laboratory Manual: Macromolecular Biophysics & Structural Characterization โšก One Night Revision → Explore All Disciplines