Neurobiology Laboratory Manual: Cellular Electrophysiology, Synaptic Physiology & Neural Circuits
Experimental protocols in intracellular glass microelectrode recordings, sciatic nerve compound action potential (CAP) conduction velocities, neuromuscular junction quantal content analysis, patch-clamp single-channel biophysics, somatosensory psychophysics, and spinal stretch reflex EMG latencies aligned with B.Sc. (Hons), M.Sc., CSIR-NET Life Sciences (Unit 7), and GATE curricula.
๐ก๏ธ Electrophysiology Rig & Neurotoxin Standard Operating Procedures (SOP)
Cellular neurophysiology practicals involve high-voltage electronic stimulators, glass capillary sharps, sensitive microelectrodes, and potent selective neuropharmacological blockers:
Intracellular Recording of Resting Membrane Potential & Action Potential Waveforms: Threshold & Refractory Kinetics
๐ฌ Principle & Biophysical Theory
The neuronal resting membrane potential ($V_m approx -70,text{mV}$) arises from asymmetric ion distributions maintained by the active $text{Na}^+/text{K}^+$-ATPase pump (pumping $3,text{Na}^+$ out for every $2,text{K}^+$ in) and the selective permeability of background leak potassium channels ($K_{text{ir}}$). Because the resting membrane is predominantly permeable to potassium ($P_K gg P_{Na}, P_{Cl}$), the resting potential approaches the Nernst equilibrium potential for potassium ($E_K approx -90,text{mV}$), accurately predicted by the Goldman-Hodgkin-Katz (GHK) equation:
$$V_m = frac{RT}{F} lnleft( frac{P_K [K^+]_o + P_{Na} [Na^+]_o + P_{Cl} [Cl^-]_i}{P_K [K^+]_i + P_{Na} [Na^+]_i + P_{Cl} [Cl^-]_o} right)$$
Upon depolarizing the membrane past threshold ($sim -55,text{mV}$), voltage-gated sodium channels ($text{Na}_V$) open rapidly. The positive feedback loop (Hodgkin cycle) causes an explosive influx of sodium ions ($P_{Na} text{ increases } sim 500text{-fold}$), driving $V_m$ toward the sodium equilibrium potential ($E_{Na} approx +60,text{mV}$), producing an overshoot of $+30$ to $+40,text{mV}$.
Repolarization is executed by two coordinated mechanisms:
- $text{Na}_V$ Inactivation: The intracellular inactivation loop ($h$-gate / IFM motif) obstructs the channel pore within $1 – 2,text{ms}$, halting further sodium influx.
- $text{K}_V$ Activation: Delayed rectifier potassium channels ($text{K}_V$) open slowly, permitting a massive outward efflux of potassium down its electrochemical gradient, driving the membrane back toward negative potentials.
- Afterhyperpolarization (AHP): Prolonged $text{K}_V$ open probability drives $V_m$ closer to $E_K$ ($sim -85,text{mV}$) before channels close, returning the cell to baseline rest.
The Absolute Refractory Period (ARP) encompasses the depolarizing and repolarizing phases where $text{Na}_V$ channels are fully inactivated ($h$-gates closed); no stimulus, regardless of intensity, can trigger another spike. The subsequent Relative Refractory Period (RRP) occurs when some $text{Na}_V$ channels have transitioned from inactivated back to closed-activatable states, but lingering $text{K}_V$ conductance and AHP require a significantly larger depolarizing current step to reach threshold.
๐ Step-by-Step Electrophysiological Protocol
- Microelectrode Pulling: Pull borosilicate glass capillaries with internal filament ($1.0,text{mm}$ OD, $0.58,text{mm}$ ID) on a Sutter P-97 horizontal micropipette puller (Heat: 520, Pull: 75, Velocity: 80, Time: 120). Fill with filtered $3.0,text{M},text{KCl}$ using a MicroFil needle. Pipette resistance should be $10 – 25,text{M}Omega$.
- Tissue Preparation & Chamber: Pin an isolated crayfish ventral nerve cord or frog sartorius muscle in an acrylic recording chamber continuously perfused with oxygenated physiological Ringer’s solution ($115,text{mM},text{NaCl}$, $2.5,text{mM},text{KCl}$, $1.8,text{mM},text{CaCl}_2$, $2.15,text{mM},text{Na}_2text{HPO}_4$, $text{pH } 7.2$).
- Electrode Zeroing & Impalement: Immerse the microelectrode into the bath solution. Null pipette offset potential to $0.0,text{mV}$ on the electrometer. Using a motorized micromanipulator, advance the electrode onto a single muscle/nerve fiber under $40times$ stereo optics. Tap the manipulator gently or deliver a high-frequency “buzz” pulse to puncture the sarcolemma/axolemma. Confirm impalement by an abrupt step-drop of voltage from $0,text{mV}$ to $-70,text{mV}$ to $-85,text{mV}$.
- Action Potential Generation: Connect a stimulator to a second intracellular current-passing microelectrode (or apply focal extracellular stimulation). Deliver square-wave depolarizing pulses of $1.0,text{ms}$ duration with increasing voltage ($0.1,text{V}$ steps). Record sub-threshold passive electrotonic potentials, note the exact threshold voltage where an all-or-none AP fires, and measure peak overshoot amplitude and duration at half-maximal amplitude.
- Refractory Period Determination: Apply dual paired stimulus pulses ($S_1$ and $S_2$, both suprathreshold) separated by a variable inter-stimulus interval ($Delta t$ decreasing from $20,text{ms}$ down to $0.5,text{ms}$). Identify the exact interval below which $S_2$ fails completely (Absolute Refractory Period, $sim 1.0 – 1.5,text{ms}$) and the interval where $S_2$ requires elevated current to fire a reduced-amplitude spike (Relative Refractory Period, $sim 2 – 5,text{ms}$).
Compound Action Potential (CAP) & Nerve Conduction Velocity (NCV): Two-Point Stimulation in Sciatic Nerve
๐ฌ Principle & Cable Theory
A peripheral nerve trunk (such as the sciatic nerve) is not a single cell, but a bundled cable containing thousands of individual motor and sensory axons wrapped in epineurium. Extracellular electrodes record the algebraic sum of electrical activity generated by all active axons within the nerve, termed the Compound Action Potential (CAP).
Unlike intracellular recordings from a single axon (which follow the strict all-or-none law), the amplitude of a CAP is graded:
- Sub-threshold: Weak electrical stimulation fails to activate any individual axons; only a stimulus artifact is visible.
- Threshold to Maximal: As stimulus voltage increases, individual axons are progressively recruited based on their axonal diameter and input resistance ($R_{in} propto 1 / d^2$). Large-diameter axons have low internal axial resistance ($r_a propto 1 / d^2$) and large surface areas, making them easiest to stimulate at low voltages.
- Supramaximal: When all axons in the nerve trunk are firing simultaneously, further increases in stimulus intensity produce no additional increase in CAP amplitude.
In a biphasic extracellular recording, as the action potential wave travels past the first recording electrode ($R_1$), that region becomes negatively charged relative to the distant second electrode ($R_2$), producing an upward deflection. When the wave arrives under $R_2$, $R_2$ becomes negative relative to $R_1$, deflecting the trace downward.
To measure absolute Nerve Conduction Velocity (NCV) without error from stimulus artifact delays or electrode polarization, the nerve is stimulated at two distinct physical locations: a proximal site ($S_1$) and a distal site ($S_2$) separated by distance $Delta d$:
$$V_{text{conduction}} = frac{Delta d}{t_1 – t_2}$$
where $t_1$ is the latency from stimulus $S_1$ to the CAP peak, and $t_2$ is the latency from stimulus $S_2$ to the CAP peak. In amphibian sciatic nerves at $20^circtext{C}$, fast myelinated $Aalpha$ motor axons conduct at $30 – 45,text{m/s}$, whereas unmyelinated $C$ fibers conduct at $< 1.5,text{m/s}$.
๐ Step-by-Step Laboratory Protocol
- Sciatic Nerve Dissection: Humanely double-pith a bullfrog (*Lithobates catesbeianus*). Slit the dorsal skin from the spinal column to the knee. Separate the gluteus and semimembranosus muscles using glass probes. Carefully free the sciatic nerve from connective fascia without stretching or pinching with metal forceps. Ligate the proximal end at the vertebral column and distal end at the knee with silk suture. Cut distal to the ligatures and transfer the $sim 60,text{mm}$ nerve trunk to frog Ringer’s.
- Nerve Chamber Mounting: Place the nerve across the platinum/silver wire array in an acrylic nerve conduction chamber. Keep the nerve moist with mineral oil or water-saturated air to prevent desiccation. Connect stimulating wires to an optically isolated stimulator (S1 and S2) and recording wires to a differential bio-amplifier ($1000times$ gain, bandpass filter $10,text{Hz} – 10,text{kHz}$). Connect central wire to true ground.
- Recruitment Curve Determination: Stimulate at proximal electrode $S_1$ with single square pulses ($0.1,text{ms}$ pulse width) starting at $0.05,text{V}$. Gradually increase voltage in $0.05,text{V}$ increments. Record the threshold voltage where the first CAP emerges, and note the supramaximal voltage where CAP amplitude saturates.
- Two-Point Conduction Velocity Measurement:
– Deliver a supramaximal pulse at proximal site $S_1$. Record latency $t_1$ from the stimulus artifact to the peak of the first biphasic wave.
– Switch stimulation to distal site $S_2$. Deliver an identical supramaximal pulse. Record latency $t_2$.
– Measure the physical distance between cathode $S_1$ and cathode $S_2$ ($Delta d$) using calipers ($50.0,text{mm}$).
– Compute conduction velocity: $V = Delta d / (t_1 – t_2)$. - Temperature Dependence ($Q_{10}$): Perfuse the chamber with cold Ringer’s ($10^circtext{C}$) versus room temperature ($20^circtext{C}$). Record the prolongation of latency and calculate the temperature coefficient $Q_{10} = (V_{20} / V_{10})^{10 / (20 – 10)}$, demonstrating temperature-dependent ion channel gating kinetics ($Q_{10} approx 1.8 – 2.2$).
Quantal Analysis & End-Plate Potentials (EPPs) at the Neuromuscular Junction: Poisson Release Statistics
๐ฌ Principle & Quantal Hypothesis
In the 1950s, Bernard Katz, Paul Fatt, and Josรฉ del Castillo discovered that acetylcholine (ACh) is discharged from motor nerve terminals in multimolecular packets or “quanta,” corresponding to the exocytosis of individual synaptic vesicles ($sim 5,000 – 10,000$ ACh molecules per vesicle).
In resting muscle, random spontaneous exocytosis of single vesicles generates small, sub-threshold depolarizations termed miniature end-plate potentials (mEPPs), with an average unitary amplitude $q_0 approx 0.4 – 0.8,text{mV}$.
Under normal physiological conditions ($[Ca^{2+}]_o approx 2,text{mM}$), a motor nerve action potential opens voltage-gated calcium channels ($text{Ca}_V2.1$), triggering the synchronized fusion of $100 – 200$ vesicles, generating a massive evoked End-Plate Potential (EPP) of $> 40,text{mV}$ that readily surpasses muscle threshold, firing a twitch action potential.
To isolate and analyze individual quantal components, the preparation is bathed in Ringer’s containing low $text{Ca}^{2+}$ ($0.2 – 0.5,text{mM}$) and high $text{Mg}^{2+}$ ($4 – 10,text{mM}$). Because transmitter release depends on the fourth power of extracellular calcium ($Release propto [Ca^{2+}]^4$), reducing calcium drastically lowers vesicle release probability ($p$). Under these conditions:
- Individual nerve stimuli elicit either zero quanta (failures, $0,text{mV}$), 1 quantum ($sim 0.4,text{mV}$), 2 quanta ($sim 0.8,text{mV}$), or 3 quanta ($sim 1.2,text{mV}$).
- The distribution of evoked EPP amplitudes fits a discrete Poisson distribution:
$$P(k) = frac{m^k e^{-m}}{k!}$$
where $k$ is the number of quanta released, and $m$ is the mean quantal content (the average number of vesicles released per impulse).
Quantal content $m$ can be derived via two independent mathematical approaches:
- Direct Ratio Method: $m = frac{overline{text{EPP}}}{overline{text{mEPP}}}$
- Method of Failures: When $k = 0$, $P(0) = e^{-m}$. Therefore:
$$m = lnleft( frac{N_{text{total}}}{N_{text{failures}}} right)$$
Agreement between these two methods confirms the quantal model.
๐ Step-by-Step Recording Protocol
- Nerve-Muscle Preparation: Dissect the frog cutaneous pectoris or sartorius muscle with its intact motor nerve. Pin the muscle stretched flat across a Sylgard-lined chamber.
- Low-Calcium Saline Perfusion: Perfuse the chamber with modified Ringer’s containing $0.3,text{mM},text{CaCl}_2$ and $6.0,text{mM},text{MgCl}_2$. (Alternatively, add $0.5,mutext{M}$ d-tubocurarine to block nicotinic receptors sub-threshold).
- Endplate Localization & Impalement: Advance a $3,text{M},text{KCl}$-filled microelectrode ($15 – 20,text{M}Omega$) near visible nerve terminal branches. Impale a muscle fiber close to the motor endplate. Verify proximity to the endplate by the presence of fast-rising spontaneous mEPPs ($< 1.0,text{ms}$ rise time). Distant impalements show slow, electrotonically attenuated waveforms and should be repositioned.
- Spontaneous mEPP Sampling: Record 200 spontaneous mEPP events without nerve stimulation. Measure peak amplitude for each event, construct an amplitude histogram, and calculate the mean unitary quantal size $overline{text{mEPP}}$ ($q_0 approx 0.42,text{mV}$).
- Evoked EPP Stimulation: Deliver 300 stimulus pulses to the motor nerve at a low frequency ($0.5,text{Hz}$ to avoid synaptic depression). For each trial, record the evoked EPP amplitude. Tabulate the number of trials yielding zero response ($N_{text{failures}}$).
- Quantal Calculation & Poisson Fitting: Calculate $m_{text{ratio}} = overline{text{EPP}} / overline{text{mEPP}}$ and $m_{text{failures}} = ln(N_{text{total}} / N_{text{failures}})$. Compare the two values (expected within $5%$ of each other). Plot the EPP amplitude distribution and overlay theoretical Poisson probability curves showing discrete quantal peaks at integer multiples of $q_0$.
Patch-Clamp Electrophysiology: Gigaseal Formation, Whole-Cell Macroscopic & Single-Channel Unitary Currents
๐ฌ Principle & Biophysical Theory
Developed by Erwin Neher and Bert Sakmann (1991 Nobel Prize), the patch-clamp technique revolutionized biophysics by allowing researchers to observe the conformational transitions of a single ion channel protein molecule in real time.
The cornerstone of the technique is the formation of a Gigaseal ($R_{text{seal}} > 10^9,Omega = 1,text{G}Omega$) between a fire-polished glass micropipette and the cell membrane. This extraordinarily tight mechanical and electrical seal reduces background thermal Johnson noise ($I_{text{noise}} propto sqrt{4kT / R}$), allowing resolution of sub-picoampere ($< 1,text{pA} = 10^{-12},text{A}$) unitary ion currents.
Four distinct configurations can be established:
- 1. Cell-Attached Mode: The pipette touches the cell and suction forms a gigaseal without rupturing the membrane. Records single channels within the patch under undisturbed physiological intracellular conditions.
- 2. Whole-Cell Mode: Applying a brief pulse of negative pressure ruptures the membrane patch inside the pipette. The pipette lumen becomes contiguous with the cytoplasm, dialyzing the cell. Clamps the membrane potential of the entire cell to record total macroscopic currents ($I = N cdot P_o cdot i$).
- 3. Inside-Out Mode: Retracting the pipette from cell-attached mode tears the patch away, exposing its cytoplasmic face directly to the bath solution. Ideal for testing intracellular second messengers ($text{Ca}^{2+}$, ATP, phosphorylation, G-proteins).
- 4. Outside-Out Mode: Retracting the pipette from whole-cell mode causes the torn membrane flaps to re-anneal across the pipette tip with the extracellular surface facing outward. Ideal for investigating neurotransmitter receptor agonists, antagonists, and channel gating kinetics.
Single channels undergo stochastic opening and closing transitions between discrete conductance states. Unitary current amplitude $i$ is governed by Ohm’s law for single channels:
$$i = gamma (V_m – V_{text{rev}})$$
where $gamma$ is single-channel conductance (in picosiemens, $text{pS}$), $V_m$ is command potential, and $V_{text{rev}}$ is reversal potential.
๐ Step-by-Step Electrophysiological Protocol
- Pipette Fabrication & Fire-Polishing: Pull thick-walled borosilicate glass pipettes to a tip resistance of $3 – 5,text{M}Omega$. Fire-polish pipette tips on a microforge under $100times$ optics to smooth rough edges and optimize lipid-glass adhesion. Fill with intracellular solution ($140,text{mM},text{KCl}$, $10,text{mM},text{HEPES}$, $1,text{mM},text{EGTA}$, $2,text{mM},text{Mg-ATP}$, $text{pH } 7.3$).
- Positive Pressure & Cell Approach: Mount pipette in an Axopatch amplifier headstage on a vibration-isolated air table. Apply $+10,text{mbar}$ positive pressure to prevent debris from adhering to the tip. Under inverted phase-contrast microscopy, lower the pipette toward a healthy, isolated HEK293 cell or cultured hippocampal neuron.
- Gigaseal Formation: Monitor pipette resistance using a $5,text{mV}$ test pulse ($50,text{Hz}$). As the pipette indents the cell surface, resistance rises slightly ($10 – 20%$). Release positive pressure and apply gentle mouth suction ($-10$ to $-20,text{mbar}$). Pipette resistance jumps from megaohms to gigaohms ($> 1,text{G}Omega$). This establishes the Cell-Attached mode.
- Whole-Cell Rupture: Compensate fast pipette capacitance ($C_{text{fast}}$). Deliver a sharp suction zap (or $200,mutext{s}$ electrical voltage zap) to breach the patch. Resistance drops, and large slow capacitance transients ($C_{text{slow}}$) appear, reflecting whole-cell membrane charging ($C_m approx 20 – 40,text{pF}$). Cancel $C_{text{slow}}$ and series resistance ($R_s$).
- I-V Curve & Single-Channel Excitation:
– In whole-cell mode, deliver voltage steps from $-80,text{mV}$ to $+60,text{mV}$ in $10,text{mV}$ increments to construct macroscopic current-voltage ($I-V$) relationship curves.
– Pull pipette away from cell to obtain an Outside-Out patch. Wash with $10,mutext{M}$ glutamate or GABA. Record stochastic square-wave unitary currents, measure step amplitude ($i = 2.5,text{pA}$), and compute single-channel conductance $gamma = i / Delta V approx 25,text{pS}$.
Cutaneous Somatosensory Psychophysics: Two-Point Discrimination & Primary Sensory Homunculus Mapping
๐ฌ Principle & Sensory Neurobiology
In 1834, Ernst Heinrich Weber established the concept of tactile spatial resolution: the Two-Point Discrimination Threshold is the minimum distance between two simultaneously applied mechanical touch stimuli required for a subject to perceive them as two distinct contact points rather than a single unified touch.
The physiological basis of two-point acuity depends directly on the peripheral density and receptive field organization of low-threshold mechanoreceptors (specifically Merkel cell-neurite complexes mediating fine static form/texture and Meissner corpuscles mediating dynamic slip):
- Fingertips & Lips (High Acuity, $sim 2 – 4,text{mm}$): Mechanoreceptor density is exceptionally high ($> 140,text{receptors/cm}^2$), and receptive fields are extremely small ($sim 2 – 3,text{mm}$ diameter). When two caliper tips press $3,text{mm}$ apart, they stimulate two distinct, non-overlapping receptive fields, activating two independent primary afferents that project along non-overlapping cortical columns in $S_1$.
- Forearm, Calf & Back (Low Acuity, $sim 35 – 50,text{mm}$): Mechanoreceptors are sparsely distributed, and multiple receptor terminals converge onto a single primary afferent, creating massive receptive fields ($> 40,text{mm}$ diameter). Two points applied $20,text{mm}$ apart fall entirely within the boundary of a single shared receptive field, sending action potentials along a single sensory axon that the brain perceives as a single touch.
This peripheral innervation density maps topographically onto the primary somatosensory cortex ($S_1$, postcentral gyrus of the parietal lobe). As mapped by Wilder Penfield, the Sensory Homunculus is heavily distorted: body parts with high receptor density and small receptive fields (hands, fingertips, lips, tongue) occupy disproportionately large cortical territory (cortical magnification factor), accounting for $> 60%$ of the primary somatosensory cortex.
๐ Step-by-Step Psychophysical Protocol
- Subject Setup & Blinding: Seat the human subject comfortably. Ensure the subject keeps their eyes closed and does not view the tested limb during all trials.
- Esthesiometer Calibration: Use a precision vernier two-point esthesiometer (or sliding tactile compass) with blunt, rounded tips. Ensure the two tips exert equal, light pressure without indenting the skin $> 1,text{mm}$ or triggering nociceptors (pain fibers).
- Method of Limits: For each anatomical site, apply random trials of either 1 tip (catch control trials to prevent guessing) or 2 tips. Begin with caliper tips wide apart (e.g., $15,text{mm}$ for fingertips, $60,text{mm}$ for back) where the subject easily detects 2 points. Gradually decrease caliper separation by $1,text{mm}$ increments (descending series) until the subject reports feeling only 1 point. Repeat in an ascending series (starting from $0,text{mm}$ and increasing until 2 points are felt).
- Testing Anatomical Sites: Systematically determine the threshold across 5 standard dermatomes:
1. Index fingertip pad (distal phalanx)
2. Thenar eminence (palm)
3. Anterior forearm (midway between wrist and elbow)
4. Upper back (scapular region)
5. Lower lip - Statistical Analysis & Cortical Mapping: Average the ascending and descending thresholds for each body region across 5 repeated trials. Construct a comparative bar graph of threshold distances versus body sites. Plot threshold distance against homuncular cortical area to demonstrate the inverse logarithmic relationship between receptive field size and cortical representation.
Monosynaptic Patellar Tendon Reflex & Surface Electromyography (EMG): Reflex Latency vs. Voluntary Motor Reaction Time
๐ฌ Principle & Neurocircuitry
The patellar (knee-jerk) reflex is the classic prototype of a monosynaptic myotatic stretch reflex. Striking the patellar tendon just below the knee cap stretches the quadriceps muscle group and its embedded intrafusal muscle spindles.
The reflex arc traverses a well-defined neuroanatomical circuit:
- Spindle Activation: Stretching the equatorial region of nuclear bag/chain fibers opens stretch-sensitive mechanosensitive ion channels in primary annulospiral sensory nerve endings.
- Ia Afferent Conduction: Action potentials travel rapidly along thick, myelinated Group Ia sensory afferents ($70 – 120,text{m/s}$) through the femoral nerve and enter the spinal cord via dorsal roots (lumbar segments L2–L4).
- Monosynaptic Central Transmission: In the ventral horn of the gray matter, Ia afferent terminals make direct excitatory glutamatergic synapses on $alpha$-motor neurons innervating the homonymous quadriceps muscle. (Concurrently, Ia collaterals excite Ia inhibitory interneurons that release glycine/GABA to inhibit $alpha$-motor neurons of the antagonist hamstring muscles, mediating reciprocal inhibition).
- Efferent Motor Output: High-velocity $alpha$-motor axons fire impulses that exit via ventral roots and travel back down the femoral nerve, releasing ACh at neuromuscular junctions to trigger an abrupt quadriceps contraction and knee extension.
Because this reflex involves exactly one central synapse ($text{synaptic delay } sim 0.7,text{ms}$) and fast myelinated fibers, the total reflex latency from tendon tap to EMG onset is exceptionally brief:
$$t_{text{reflex}} approx 18 – 25,text{ms}$$
In contrast, voluntary motor reactions (e.g., kicking the leg upon hearing the hammer tap) require ascending sensory transmission to the auditory/sensory cortex, associative cortical decision-making, and descending pyramidal corticospinal tract conduction, yielding latencies of:
$$t_{text{voluntary}} approx 150 – 220,text{ms}$$
๐ Step-by-Step EMG Protocol
- Electrode Placement & Skin Prep: Clean the skin over the right rectus femoris muscle with alcohol wipes to reduce skin-electrode impedance $< 5,text{k}Omega$. Attach two surface $text{Ag/AgCl}$ recording electrodes along the muscle belly ($3,text{cm}$ inter-electrode distance), and attach a reference ground electrode over the electrically neutral bony patella or tibial tuberosity.
- Instrumented Reflex Hammer: Connect an electronic reflex hammer containing a piezoelectric or contact switch to the digital input channel of the bio-data acquisition system (PowerLab / Biopac), synchronizing the exact moment of tendon impact with the EMG recording.
- Patellar Reflex Recording: Seat the subject comfortably on an elevated examination table with legs hanging freely and relaxed. Strike the patellar tendon firmly with the hammer. Record 10 reflex trials. Measure the reflex latency ($t_{text{reflex}}$) from the initial hammer impact pulse to the onset of the compound muscle action potential (EMG burst). Calculate mean latency ($sim 21.4,text{ms}$).
- Voluntary Reaction Time Trial: Instruct the subject to voluntarily kick their leg forward as rapidly as possible immediately upon hearing or feeling the hammer tap. Record 10 voluntary trials and compute mean voluntary latency ($sim 185,text{ms}$). Note that voluntary latency is approximately $8 – 10times$ longer than the spinal monosynaptic reflex.
- Jendrassik Maneuver Facilitation: Instruct the subject to link the flexed fingers of both hands together across their chest and pull forcefully outward immediately before the tendon tap. Observe that the EMG amplitude of the reflex burst increases substantially ($2 – 3times$ higher voltage). This facilitation occurs because descending voluntary corticospinal drive decreases presynaptic inhibition on Ia terminals in the spinal cord, elevating motor neuron excitability.
Comprehensive Practical Viva-Voce Examination & Electrophysiology Assessment Bank
Essential questions testing understanding of action potential ionic biophysics, nerve conduction velocity, quantal release mathematics, patch-clamp gigaseals, receptive field somatotopy, and monosynaptic reflex circuits:
Ans: The Nernst equation calculates the equilibrium potential for a single ion. The GHK equation accounts for the simultaneous contributions and relative permeabilities of multiple ions (K+, Na+, Cl-) across the cell membrane.
Ans: Because voltage-gated Na+ channels inactivate very rapidly (h-gates close), and delayed rectifier K+ channels begin opening concurrently, counteracting sodium depolarization before E_Na can be fully attained.
Ans: The intracellular loop between domains III and IV, containing the hydrophobic IFM (Isoleucine-Phenylalanine-Methionine) motif, which swings into the open pore like a hinged lid to block ion permeation.
Ans: In absolute refractory period, NaV channels are fully inactivated and cannot open regardless of stimulus strength. In relative refractory period, some NaV channels have reset to closed-activatable states, but lingering KV efflux requires a stronger-than-normal depolarizing stimulus to reach threshold.
Ans: Because a nerve trunk contains thousands of distinct axons with differing diameters, thresholds, and conduction velocities; increasing stimulus voltage progressively recruits more individual axons into the compound sum.
Ans: Because it eliminates time delays caused by the initial stimulus artifact, electrode-tissue interface polarization, and neuromuscular synaptic transmission.
Ans: An mEPP is a small spontaneous sub-threshold depolarization (~0.4 mV) caused by the random exocytosis of a single acetylcholine vesicle. An evoked EPP is the synchronized multi-quantal depolarization triggered by nerve impulse-driven Ca2+ influx.
Ans: Because transmitter release has a fourth-power dependence on [Ca2+]o; drastically lowering calcium reduces release probability so that nerve stimuli release only 0, 1, or 2 quanta, enabling Poisson statistical analysis.
Ans: A gigaseal is an extremely tight electrical seal (> 1 Gigaohm) formed between the glass pipette tip and the cell membrane. It prevents current leakage around the pipette and reduces thermal Johnson noise, allowing detection of sub-picoampere single-channel currents.
Ans: Inside-out exposes the cytoplasmic face of the membrane patch to the external bath (ideal for testing intracellular second messengers like Ca2+ or cAMP). Outside-out exposes the extracellular face to the bath (ideal for testing neurotransmitter receptor agonists and drugs).
Ans: i = gamma * (Vm – Vrev), where i is the unitary single-channel current, gamma is the single-channel conductance in picosiemens (pS), Vm is membrane potential, and Vrev is reversal potential.
Ans: Fingertips have an extremely high density of mechanoreceptors with small, non-overlapping receptive fields, whereas the back has sparse mechanoreceptors that converge onto single sensory neurons with large receptive fields.
Ans: A topographical cortical representation of the human body in the postcentral gyrus (S1). Cortical magnification reflects the fact that body regions with high tactile receptor density (fingers, lips) occupy disproportionately large areas of cortex.
Ans: Muscle spindles, specifically the intrafusal nuclear bag and chain fibers wrapped by Group Ia primary annulospiral sensory nerve endings.
Ans: Muscle spindle -> Ia sensory afferent via femoral nerve -> dorsal root ganglion -> monosynaptic excitatory synapse in ventral horn of L2-L4 -> alpha-motor neuron -> femoral nerve efferent -> motor endplate on quadriceps.
Ans: A concurrent disynaptic circuit where Ia afferent collaterals excite Ia inhibitory interneurons in the spinal cord, which release glycine/GABA to inhibit alpha-motor neurons of the antagonist flexor (hamstring), preventing resistance to extension.
Ans: The reflex arc involves only one central synapse and travels entirely within spinal cord pathways. Voluntary movement requires ascending transmission to the brain, cortical processing across sensory/motor areas, and descending corticospinal conduction.
Ans: Isometric contraction of distant muscles (e.g., clasping hands and pulling apart) during the tendon tap; it reduces descending presynaptic inhibition on Ia terminals in the spinal cord, elevating alpha-motor neuron excitability and amplifying the reflex EMG burst.
Ans: Tetrodotoxin (TTX), a potent neurotoxin found in pufferfish (*Tetraodontidae*), which physically plugs the outer selectivity filter pore of NaV channels with nanomolar affinity.
Ans: Tetraethylammonium (TEA), which binds to the inner or outer vestibule of voltage-gated potassium channels (KV), blocking outward K+ currents.
Synthesize with Theoretical Neurobiology
Connect electrophysiological observations with master theory modules in ion channel biophysics, synaptic plasticity (LTP/LTD), and sensory coding circuits.